3 environmental, 4 system alarm board, Environmental – ADLINK cPCIS-ET2600 Series User Manual
Page 46: System alarm board
 
40
•
Specifications
6.3 Environmental
•
Operating Temperature: -20°C to 50°C (Supports operation up to 70°C 
but with derating above 50°C. Power efficiency will be derated by 2.5% 
for every degree Celsius with only 50% power efficiency at 70°C, i.e. 
125W/PSU.) 
• Storage
Temperature: -40 to 85°C.
•
Humidity: 5% - 95%, non-condensed.
•
Shock: 15G peak-to-peak, 11ms duration, non-operation.
• Vibration:
o
Non-operation:1.88Grms, 5 – 500Hz, each axis.
o
Operation: 0.5Grms, 5 – 500Hz, each axis. 
 
 
6.4 System
Alarm
Board
•
Supports fault alarm for up to 8 fans. If any fan faults, the ALARM LED 
will flash and an audible alarm will sound 
•
Can detect temperature at two different locations.
•
Trigger temperature for each sensor can be set independently (50°C, 
60°C, 70°C). 
• Alarm
mute
•
LED indicators for fan and temperature status