5.1.4. Exception Codes

In case of an error, the BMC drives a blinking code on the blue Status LED (LED1). The same error code is also reported by the BMC Flags

register. The Exception Code is not stored in the Flash Storage and is cleared when the power is removed. Therefore, a “Clear Exception
Code” command is not needed or supported.

Exception Code

Error Message

0 NOERROR

2 NO_SUSCLK

3 NO_SLP_S5

4 NO_SLP_S4

5 NO_SLP_S3

6 BIOS_FAIL

7 RESET_FAIL

8 POWER_FAIL

9 LOW_VIN

10 VCORE

11 VGFX

12 V1P05S

13 VMEM

14 V1P0A

15 V3P3A

16 +P12V_5V

18 CRITICAL_TEMP

19 NO_CB_PWROK

20 NO_HW_PWORK

21 NO_V1P24A_PG

5.1.5. BMC Flags

The BMC Flags register returns the last detected Exception Code since power-up and shows the BIOS in use and the power mode.

Bit

Description

[ 0 ~ 4 ]

Exception Code

[ 6 ]

0 = AT mode
1 = ATX mode

[ 7 ]

0 = Standard BIOS
1 = Fail-safe BIOS.