System management > power up, System management > lvds backlight, System management > smart fan – ADLINK cExpress-BT2 User Manual
Page 46
 
Page 46
cExpress-BT2
7.2.6.6. System Management > Power Up
Feature
Options
Description
Power Up
Info only
Power Up watchdog
Attention: F12 disables the Power Up 
Watchdog. 
Enabled 
Disabled 
The Power-Up Watchdog resets the system after a certain 
amount of time after power-up. 
ECO
Mode
Disabled 
Enable 
Reduces the power consumption of the system
Power-up
Mode
Attention: The Power-Up Mode only has effect, 
if the module is in ATX-Mode. 
Turn on 
Remain off 
Last State 
Turn On: The machine starts automatically when the power 
supply is turned on. 
Remain Off: To start the machine the power button has to be 
pressed. 
Last State: When powered on during a power failure the system 
will automatically power on when power is restored. 
7.2.6.7. System Management > LVDS Backlight
Feature
Options
Description
LVDS Backlight
Info only
LVDS Backlight Bright
255
The value range starts at 0 and ends at 255.
7.2.6.8. System Management > Smart Fan
Feature
Options
Description
Smart Fan
Info only
CPU Smart FanTemperature Source
CPU Sensor 
System Sensor 
Select CPU smart fan source
CPU Fan Mode
AUTO (Smart Fan) 
Fan Off 
Fan On 
Select CPU fan mode
CPU Trigger Point 1
Read only
Trigger Temperature
15
Specifies the temperature threshold at which the BMC turns on 
the CPU fan with the specified PWM level 
PWM Level
30
Select PWM level
CPU Trigger Point 2
Read only
Trigger Temperature
60
Specifies the temperature threshold at which the BMC turns on 
CPU fan the specified PWM level 
PWM Level
40
Select PWM level
CPU Trigger Point 3
Read only
Trigger Temperature
70
Specifies the temperature threshold at which the BMC turns on 
CPU fan the specified PWM level 
PWM Level
63
Select PWM level
CPU Trigger Point 4
Read only
Trigger Temperature
80
Specifies the temperature threshold at which the BMC turns on 
CPU fan the specified PWM level 
PWM Level
100
Select PWM level