Thermal/cooling requirements, Figure 2-12. stack heights of cooling assemblies, Table 2-7 – ADLINK ETX-PVR User Manual

Page 23: Adlink optional cooling solutions

Advertising
background image

Chapter 2

Product Overview

ETX-PVR

Reference Manual

17

Thermal/Cooling Requirements

The CPU, I/O Hub, and voltage regulators are the main sources of heat on the board.The ETX-PVR is
designed to operate at the maximum speeds of the N455 (1.66GHz) or N525 (1.80GHz) CPUs and requires

a cooling solution. ADLINK offers two cooling solutions, as well as a heat spreader platform on which to

build a cooling solution (see

Table 2-7

for descriptions of the cooling solution options.)

Figure 2-12

provides

the height measurements from the bottoms of the ETX connectors to the tops of the cooling components.

Figure 2-12. Stack Heights of Cooling Assemblies

NOTE

The overall system design must keep the ICs within their operating temperature
specifications.

Table 2-7. ADLINK Optional Cooling Solutions

Cooling Solution

Description

Passive Heat Sink
(without fan)

Qualified to maintain optimal performance up to +70°C.

Active Heat Sink
(with fan)

Qualified to maintain optimal performance up to +85°C.

Heat Spreader

Provides a simple thermal platform on which to build a cooling solution.

NOTE

All heights are given in inches.

Heat Spreader

ETX-PVR
COM Board

0.52

ETX
Connector

ETX-PVR_Cooling_Ht_b

ETX-PVR with Heat Spreader

Heat
Sink

ETX-PVR
COM Board

ETX
Connector

2.23

ETX-PVR with Active Heat Sink (Fan)

Heat
Sink

ETX-PVR
COM Board

ETX
Connector

1.56

ETX-PVR with Passive Heat Sink (no Fan)

Advertising