COMMAND

DESCRIPTION

0x20

Set/Clear Watchdog-timer

0x21

Reserved for BIOS Timeout Counter

0x22

Set timeout of Watchdog-timer on power-up

0x26-0x28

Reserved for Softstraps

0x2E

Clear Exception Code

0x2F

Get SMC Capability

0x30

Read Version-String 1

0x31

Read Version-String 2

0x32

Read Total Ontime Minutes

0x33

Read Ontime Seconds since Power-Up

0x34

Read Power Cycles

0x35

Read SMC Flags

0x36

Get last System Restart Event

0x37

Read current CPU Temperature

0x38

Read current Board Temperature

0x39

Get Min/Max-Temperatures (Temperature Logger)

0x3A

Get Startup-Temperatures of CPU and Board

0x3B

Get number of PROCHOT#-Events

0x3C

Get number of TS#-Events

0x3D

Get SMC-Status

0x3F

Read Version-String of Bootloader

0x40

Set Address/Length for Flash Access

0x41

Write Data to User-Flash

0x42

Read Data from User-Flash

0x43

Clear all Data in User-Flash

0x44

Write-protect SECURE-Area

0x60-0x67

Get Voltages

0x68

Get Fan-Speed

0x69

Get Main Current (Power Monitor)

0x70-0x77

Get Board Manufacturing Data

0x80

Set Backlight PWM

0x81

Get Backlight PWM

0x90-0x97

Reserved for Board specific internal communication

Table 3.1 SMC Command Codes