4.8 Read Power Cycles

This command reads the Power Cycles of the System. The Power-cycle-counter has a 32-bit (four
byte wide) size and is updated every time when the System is Powered-ON in the Flash of the SMC.

The Most Significant Byte is sent first, followed by the next highest Byte down to the Least
Significant Byte (Table 4.8.1).

START

SMC_addr

ACK command

ACK START (Repeat)

SMC_addr+1

ACK

length

ACK(C) Byte 1 (MSB) ACK(C) … ACK(C)

Byte 4 (LSB) ACK(C) STOP

Table 4.8.1 SMC transmitter format of the Power Cycles Command Code

ITEM

DESCRIPTION

START

SM-bus start condition

SMC_addr

0x50 (8-bit)

ACK

SM-bus acknowledge condition generated by receiver

command

0x34 = “Read Power Cycles” Command code

length

0x04 = 4 Bytes data length

Byte 1-4

Value of Power Cycle Counter

STOP

SM-bus stop condition

Table 4.8.2 Explanation of Table 4.8.1