2 smc standard transmitter format (read cycle), 2 smc – ADLINK CoreExpress-ECO2 User Manual
Page 9
Advertising
![background image](/manuals/733601/9/background.png)
2.2 SMC
STANDARD
TRANSMITTER
FORMAT
(
READ
CYCLE
)
The SMC transmitter format is shown in Table 2.2.1.
START SMC_addr ACK command ACK
START (Repeat) SMC_addr+1 ACK
length ACK(C)
data_byte
ACK(C) n-bytes
ACK(C) STOP
Table 2.2.1 SMC transmitter format (direction of length and data-bytes changed)
ITEM
DESCRIPTION
START
SM-bus start condition
SMC_addr
0x50 (8-bit) (send by chipset)
ACK(C)
SM-bus acknowledge (send by chipset)
ACK
SM-bus acknowledge (send by SMC)
command
Selected Command (send by chipset)
length
Number of Data-bytes (send by SMC)
data_byte
data byte transmitted to SMC receiver (send by SMC)
n-bytes
more data bytes transmitted to SMC receiver (send by SMC)
STOP
SM-bus stop condition
Table 2.2.2 Explanation of Table 2.2.1