27 get board manufacturing data – ADLINK CoreExpress-ECO2 User Manual

Page 33

Advertising
background image

4.27 Get Board Manufacturing Data

These commands reads the contents of the 8 Data-Fields. The Manufacturing Data gives information
about the Board-Serial-Number, BIOS-Version, Test-Date, etc. Each command receives 1 length

Byte and 16 Bytes of Data.

START SMC_addr ACK command ACK START (Repeat) SMC_addr+1 ACK length ACK(C)

Byte 1

ACK(C) …

ACK(C) Byte 16

ACK(C) STOP

Table 4.27.1 SMC transmitter format of the Get Board Manufacturing Data Command Code

ITEM

DESCRIPTION

START

SM-bus start condition

SMC_addr

0x50 (8-bit)

ACK

SM-bus acknowledge condition generated by receiver

command

“Get Board Manufacturing Data” Command code:

0x70: BOARD PART NUMBER

0x71: BOARD SERIAL NUMBER

0x72: BIOS VERSION

0x73: TEST DATE

0x74: For Future data

0x75: For Future data

0x76: For Future data

0x77: For Future data

length

0x10 = 16 Bytes data length

Byte 1-16

ASCII-Byte of Information String

STOP

SM-bus stop condition

Table 4.27.2 Explanation of Table 4.27.1