16 get number of ts#-events – ADLINK CoreExpress-ECO2 User Manual

Page 24

Advertising
background image

4.16 Get Number of TS#-Events

This command reads the TS#-Event-counter. TS# is asserted by a Temperature sensor when a
device reaches it’s critical temperature and released when the device is back into its normal

temperature range. This counter gives the User an information of Temperature/Cooling problems.
This counter is cleared when the system is removed from power.

Depending on the board this command reflects the status of different devices. Please look at the
board technical manual chapter “LEMT functions” for details.

START

SMC_addr

ACK command

ACK START (Repeat)

SMC_addr+1

ACK

length

ACK(C) Byte 1 (MSB) ACK(C) … ACK(C)

Byte 4 (LSB) ACK(C) STOP

Table 4.16.1 SMC transmitter format of the Get Number of TS#-Events Command

ITEM

DESCRIPTION

START

SM-bus start condition

SMC_addr

0x50 (8-bit)

ACK

SM-bus acknowledge condition generated by receiver

command

0x3C = “Get Number of TS#-Events” Command code

length

0x04 = 4 Bytes data length

Byte 1-4

Value of TS#-Counter

STOP

SM-bus stop condition

Table 4.16.2 Explanation of Table 4.16.1