Introduction

11

MXC-6000

nect) connector on the front panel. The onboard digital I/O card
supports the following features:

16-CH Isolated DI

X

Logic high: 5 to 24 V

X

Logic low: 0 to 1.5 V

X

Input resistance: 2.4K @ 0.5W

X

Isolation type: photocoupler

X

Isolation voltage: 2500 V RMS

X

Interrupt source: DI channel 0 and 1

16-CH Isolated DO

X

Output Type: MOSFET transistor

X

Sink current up to 100 mA (sustained loading) or 250 mA
(peak loading) on each isolated output channel

X

Supply voltage: 5 to 35 V DC

X

Isolation type: Digital Isolator

X

Isolation voltage: 2500 VRMS

X

Flywheel diode for VDD on all DO channels

Isolated 5V DC Power Source for DO

X

Supply voltage: 5 to 0.5V DC

X

Supply current: 180 mA (maximum)

X

Isolation type: DC-to-DC transformer

X

Isolation voltage: 1000 VRMS (channel to system)

General Specification

68-pin VHDCI(Very High Density Cable Interconnect) connector
(mating with AMP 787082-7) on the front panel

Optional accessories: DIN-68S-01 and ACL-10568-1

Data transfer: programmed IO

Software Driver support: PCIS-DASK for Windows