Delta RMC101 User Manual

Page 280

Advertising
background image

RMC100 and RMCWin User Manual

5-30

good reference for this information.

Input to Event mode does not require multiple inputs to be switched simultaneously. For this
reason, many applications can use the RMC without a controlling PLC. The following points
describe the operation of Input to Event mode:

• Parameters and tables used by the RMC are configured using the RMCWin software and stored

in the RMC Flash memory.

• All axes are initialized by raising the Run/Stop (CPU input 0) line on the RMC, and all axes are

immediately stopped by the falling of the Run/Stop line. Therefore, the Run/Stop input is often
connected to the system’s emergency-stop button.

• The Ready (CPU output 0) line echoes the Run/Stop input line to notify the controlling system

when the RMC is initialized.

• When the Run/Stop line is raised and a Trigger (DI/O inputs 0-15) input rises or falls, the Input to

Event table is used to determine which axes receive an event sequence.

The Input to Event table has a row for each edge (rising and falling) of each Trigger input (32 rows
total). Each of these rows has a field for each axis; each field may either be left blank or hold an
Event Step number (0 to 255).

When an edge occurs on a Trigger input, each axis’s field in the row corresponding to the input
edge that took place is checked. For each field containing a valid value, the axis starts executing
the event sequence beginning with the Event Step number given by the Input to Event table entry.

• Each time the Run/Stop or a Trigger input transitions, the Acknowledge (CPU output 1) line

toggles. Stand-alone applications generally ignore this, but PLC-controlled applications may wish
to use this signal.

• The eight Status outputs (DI/O outputs 0-7) default to being used for the following:

DI/O

Output

#


2-4 Axis
RMC’s


5-8 Axis
RMC’s

0

Axis 0 In
Position

Axis 0 In
Position

1

Axis 1 In
Position

Axis 1 In
Position

2

Axis 2 In
Position

Axis 2 In
Position

3

Axis 3 In
Position

Axis 3 In
Position

4

Axis 0 Stop
on Error

Axis 4 In
Position

5

Axis 1 Stop
on Error

Axis 5 In
Position

6

Axis 2 Stop
on Error

Axis 6 In
Position

7

Axis 3 Stop
on Error

Axis 7 In
Position

Advertising
This manual is related to the following products: