Appendix B: Command Field Reference

B-13

0xDF


This chart shows commands that can be issued to pressure axes:

Description

ASCII

Decimal

Hex

Set Pressure Set A

|

124

0x7C

Set Bias Drive

B

66

0x42

Start Events

E

69

0x45

Set Mode

M

77

0x4D

Open Loop

O

79

0x4F

Set Parameters

P

80

0x50

Quit Events

Q

81

0x51

Set Pressure Ramp Time

\

92

0x5C

Set Pressure

^

94

0x5E

Set Pressure Set B

_

95

0x5F

Set Parameter on-the-fly

None

208-223

0xD0-

0xDF

B.2 Pressure/Force Command Fields

B.2.1 Mode (Pressure/Force)

Default: 0x0000

Bits in the Mode word determine the way the RMC regulates pressure. Bit 15 is the MSB and bit 0
is the LSB.

Click here for the Mode Bit Map

Bit 5 - Ramp Mode Type
If this bit is set, the pressure ramps linearly. If this bit is cleared, the pressure ramp is an S-curve.
It is recommended that this bit be left cleared, as it is much smoother and easier for the hydraulic
system to track curved ramps. Notice that the Ramp Time field is used differently for the two
modes when entering pressure. In S-curve mode the entering pressure ramp is only a half ramp
(the deceleration), so only half the Ramp Time is used for the half ramp. Linear mode ramps have
no acceleration/deceleration phases, so the Ramp Time field always refers to the entire ramp and
is therefore not divided by two.