Ssi led indicators, Ssi led indicators -74, 4 ssi led indicators – Delta RMC101 User Manual

Page 618

Advertising
background image

RMC100 and RMCWin User Manual

6-74

2 = 0.01 mm (10 µm)

3 = 0.05mm (50 µm)

4 = 0.1 mm (100 µm)

5 = 0.02 mm (20 µm)

6 = 0.002 mm (2 µm)

This setting does not affect the SSI Configuration dialog, but must be taken into account when
setting the Scale.


d: Performance

1 = Standard

This setting does not affect the Configuration word.


e, f: Scale Orientation

00 = Forward-acting

01 = Reverse-acting

02 = Forward-acting, Synchronized

This setting does not affect the Configuration word.

Note:

It is highly recommended that a Synchronized transducer (Scale Orientation of 02) be

selected. This ensures that the time between position samples matches the control loop time of
the RMC controller. If the transducer is not synchronized, the sample time may not match and
make precise speed control difficult.

See also:

SSI Overview

SSI Wiring

SSI LED Indicators

SSI Specifications

6.6.4 SSI LED Indicators

The two LEDs above the Drive connector on the RMC’s SSI interface card are axis status LEDs.
These LEDs will reflect the operational status of their corresponding axis according to the
following table.

LED Action

Axis Status

Continuous Red

One or more of these errors have

Advertising
This manual is related to the following products: