Offset elbow installation – DuraVent DuraTech 5-8 User Manual

Page 12

Advertising
background image

12

may be constructed with standard framing

and sheathed with sheetrock or plywood.

Important: Use Wall Straps every 8’ min to

maintain a minimum of 2” of air space between

the chimney and combustible materials.

OFFSET ELBOW INSTALLATION

Elbows are manufactured in 15° and 30°

angles measured from the vertical. In the

US, a 30° Elbow is the largest that can be

used in an offset. A 30° Elbow may not be

combined with a 15° Elbow to make a 45°

offset. Elbows inhibit draft, avoid their use

where possible. When Elbows are necessary

to avoid obstructions such as rafters, etc, use

no more than 2 pairs of Elbows in any one

chimney system.

1. Attach Elbows: Attach Elbow to Chimney

Section or other Elbow by twisting clockwise

until they lock firmly. Attach one Elbow to the

Chimney Section below, and align it for the

offset. Elbows for DuraTech have a swivel

feature that allow for 360º rotation at their base

for ease of installation. Refer to Table 3 to

determine the required offset length and attach

an appropriate length (or lengths) of Chimney

Section(s) above the Elbow. Important:

For each chimney pipe section in the offset

(between the elbows), there must be an Elbow

Strap, Tee Support, or similar support method

to support the weight of the pipe and to relieve

stress on the Elbows. Attach the second Elbow

above the Chimney Section to complete the

offset (Fig.17).

2. Secure Offset: Place the Elbow Strap’s

band around the angled portion of the top

Elbow, then tighten the nut and bolt until

the clamp is firm. There are both dedicated

diameter, and Universal components available,

Wrap the Elbow Strap end over an adjacent

joist or rafter and secure it with at least (2)

8-penny nails or (2) #8, 1-1/2 screws. Do not

TABLE 3: Offset Chart

Elbow

Angle

from

Vertical

Chimney

Length

Between

Elbows

Offset

Inches

Rise

Inches

15”

0”

2”

16 ½”

15”

6”

3 ¼”

21 ¼”

15”

12”

4 ¾”

27

15”

18”

6 ¼”

32 ¾”

15”

24”

8”

38 ½”

15”

36”

11”

50 ¼”

15”

48”

14 ¼”

61 ¾”

15”

48” + 6”

15 ½”

66 ½”

15”

48” + 12”

17”

72 ¼”

15”

48” + 18”

18 ½”

78:

15”

48” + 24”

20”

83 ¾”

30”

0”

4”

15 ¾”

30”

6”

6 ¼”

30”

12”

9 ¼”

25 ¼”

30”

18”

12 ¼”

30 ¼”

30”

24”

15 ¼”

35 ½”

30”

36”

21 ¼”

46”

30”

48”

27 ¼”

56 ¼”

30”

48” + 6”

29 ¾”

60 ½”

30”

48” + 12”

32 ¾”

65 ¾”

30”

48” + 18”

35 ¾”

71”

30”

48” + 24”

38 ¾”

76”

add more Chimney Sections until the Elbows

are supported. Be sure that the chimney

remains vertical. If there is more than one

Chimney Section between the Elbows, install a

second Elbow Strap around the joint of the two

Chimney Sections (Fig.17).

Advertising