DuraVent DuraTech 5-8 User Manual

Page 8

Advertising
background image

8

3. Install Support Box: For installation into a

flat ceiling, there is the option of the Round

Support Box (Round or Square Trim Collar),

Flat Ceiling Support Box, Square Ceiling

Support Box, Reduced Clearance Support

Box, or the Combustion Air System (CAS)

Ceiling Support Box. The CAS Ceiling

Support is only used when installing the

CAS system, refer to the DuraTech CAS

Installation Instructions for directions on how

to install the remainder of the system. The Flat

Ceiling Support Box is primarily used for Oil

Appliances and comes unpainted.

For the Round support box, the trim mounts

flush to the ceiling with the bottom protruding

a min of 3” below the ceiling (Fig.7). For the

Square support box, the square face must

protrude a min of 2” below the ceiling (Fig.7).

Level the Support Box and secure it to the

framing using at least three 8-penny nails

per side (min. of 12 total). Alternatively, you

may use 1-1/2” #8 wood screws (min. of 12

total), instead of nails. After the Support Box

is mounted, secure the Trim Collar (round or

square) to the framing members using the (4)

1” long, round-head wood screws provided

Figure 9

Figure 8

REF FIG. 7 FOR MIN

DISTANCE BELOW

CEILING FOR

SUPPORT USED

18 INCHES

MINIMUM FOR

SINGLE WALL

STOVEPIPE

ADJUSTABLE FLASHING

CHIMNEY SECTIONS

ATTIC INSULATION SHIELD

ROUND TRIM COLLAR

FRAMED OPENING

ROUND SUPPORT

BOX

CHIMNEY CAP

STORM

COLLAR

(Fig.9). For installation into a cathedral ceiling,

you must use the Square Ceiling Support

Box or Reduced Clearance Support Box (or

the CAS Ceiling Support if installing the CAS

system) and the two-piece Trim. The bottom

of the square portion of the Support Box must

be a minimum of 2” lower (round portion is

then an additional 3” lower) than the finished

ceiling at the lowest side of the penetration

(Fig.9). Level the Support Box and secure it

to the framing using at least three (3) 8-penny

nails per side (minimum of 12 nails total), or a

minimum of (3) #8, 1-1/2” wood screws. Adjust

SQUARE SUPPORT BOX

WITH TRIM FRAME IN

PLACE

WOOD SCREWS ARE

REQUIRED

MINIMUM OF

2” BELOW

CEILING

Advertising