Adjustable chimney length, Figure 34 figure 33 – DuraVent DuraTech 5-8 User Manual

Page 22

Advertising
background image

22

2” of clearance to combustibles, and enclose

the chimney where it passes through occupied

areas.

ADJUSTABLE CHIMNEY LENGTH

The DuraTech Adjustable Length is used when

an exact length of chimney is needed and

standard lengths of chimney are not sufficient.

The Adjustable Length spans from 15”-22”

(Fig.34) and can be used between any other

DuraTech chimney sections (straight pipe

lengths, elbows, tees, etc.).

1. Determine the length needed for your

installation. There will be 1-1/4” lost to the joint

between the Adjustable piece and the next

section of chimney.

2. Remove insulation strips from male end

of pipe, as needed, depending on the length

required for your installation (Fig.33). Be very

careful on how much, if any, insulation is re-

moved from the male section. Refer to Table 4.

WARNING: The entire Adjustable Length

must be filled with insulation, without gaps.

Failure to ensure the insulation is continu-

ous can result in a fire hazard.

3. Slide the two sections of the Adjustable

Figure 31

Figure 32

ANCHOR

PLATE

MASONRY

ANCHOR BOLTS

(4) REQUIRED

(NOT

FURNISHED)

EXISTING

MASONRY

CHIMNEY

WITH LEVELED

SURFACE

HIGH TEMP

SEALANT

MAINTAIN 1 INCH MIN

CLEARANCE FROM ANCHOR

PLATE TO COMBUSTIBLES

SHEET METAL

SCREWS

(4 REQUIRED)

CHIMNEY

SECTION

ANCHOR

PLATE

NOTE:

Follow local

building code

requirements

for connecting

factory-built

chimney to

masonry

fireplaces.

Figure 34

Figure 33

2” WIDE

INSULATION

STRIPS

15” - 22”

MALE END

SECTION

ADJUST LENGTH BY

REMOVING INSULATION

STRIPS (TABLE 1)

MIN 2”

OVERLAP

FEMALE END

SECTION

Advertising