DuraVent DuraTech 5-8 User Manual

Page 19

Advertising
background image

19

screws. Once the chimney is at the minimum

height specified in Fig.1, attach the Chimney

Cap onto the top of the chimney by holding

it by the collar and twist locking it clockwise

onto the Chimney Pipe. If the chimney

penetrates an overhang, frame for at least 2”

of clearance, and install Flashing and Storm

Collar as described in Steps 9 & 10 for “Ceiling

Supported” Installations. Another option is

to cut away the overhang for a 2” clearance

(Fig.28). If the chimney extends more than 5’

above the top Wall Strap or Flashing, use an

Extended Roof Support Bracket.

9. Install Chase Top Flashing: It is

recommended that a Tee Supported Chimney be

enclosed in a chase. If a chase enclosure has

been constructed, you can either use a standard

flat-roof flashing, or you can use a Chase Top

Flashing. Using a Chase Top Flashing allows

for a lower profile for the chimney. The Chase

Top Flashing has an opening that is 3” larger

in diameter than the DuraTech Chimney. If the

Chase Top Flashing can fit over your chase

enclosure as required (Fig.29) then install as

directed, or trim as needed. However, if the

Chase Top Flashing is smaller than your chase

enclosure, you will need to provide a galvanized

sheet capable of covering your chase and

overhanging the sides by 1/2 - 3/4 inch. Attach

the Chase Top Flashing to the galvanized sheet

using appropriate sheet metal screws and non-

hardening waterproof sealant. Use the Chase

Top Flashing Spacers to allow the proper air-gap

clearances on the galvanized sheet. The Chase

Top Flashing Spacers are available to insure

that the proper air-gap is maintained. Fig.29

displays how these air gaps are established using

the Spacers and Chase Top Flashing. Secure

the Chase Top Flashing to the chase using a

sufficient number of #8, 1-1/2” wood screws,

ensure the air gap is maintained between the

flashing and the chase. Seal the screw heads

with non-hardening sealant. When installing the

Storm Collar, allow a 1” air space between the

Figure 27

EXTENDED ROOF

SUPPORT BRACKET

ADJUSTABLE WALL

STRAP

ADJUSTABLE

FLASHING

2 INCHES MIN

FRAMED CHASE
ADJUSTABLE TEE

SUPPORT

ACCESS DOOR

FOR CLEANING

2 INCHES MIN

6 INCHES MIN

INTO ROOM

Figure 26

MIN 6 INCHES

CLEARANCE

BETWEEN CAP AND

CHASE TOP

ACCESS DOOR

FOR CLEANING

CHASE TOP

FLASHING

FRAMED EXTERIOR

ENCLOSURE

TYPICAL THRU-

THE-WALL TEE

SUPPORTED

INSTALLATION

Advertising