2.6 Control Wiring

Radio Receiver
Limited to 250 ma.

Open direction non-contact sensor.
Stops the gate in the open cycle only.
Gate resumes normal operation when
the obstruction is cleared.

Close direction non-contact sensor.
Reverses gate during the closing
cycle only. Holds gate in the full open
position until obstruction is cleared.

Power (24 Volt DC)
and logic output.
Power is shut off
.5 sec. prior to gate
starting and remains
off while gate is
opening and in the
open position.

Convenience open radio
receiver wiring may differ.
See section 5.1 for more info.

Com

Com

Com

Relay

Red Open

Green Close

White Com

24 Volt

24 V

Com

Com

Key Switch

Stand-Alone
Keypad

Stand-Alone
Card Reader

Telephone
Entry

Photo Cells

B

B

A

A

A

Note: All stand-alone
and telephone entry
devices must use a
separate power
source.

Fire Box

When SW 1, switch 5 is OFF,
terminal 15 will function as a
normal “Reverse Input” and will
reverse the gate during a close
cycle if the photo cell beam gets
obstructed.

11

ON

2

3

4

5

6

7

8

SW 1

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

NC

NO

POWE

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8

Magnetic
Lock

3-Button Station

DoorKing ONLY

1 2 3 4 5 6

8

7

4502

Auxiliary Terminal

Diagram at right is for illustration purposes. The actual

placement of the secondary protection devices is dependent on
the specific installation requirements.

Secondary entrapment protection devices must be installed

with this gate operator. This protection may be provided by
non-contact or contact sensors, or a combination of both.

Secondary device wiring shows inputs to the circuit board

only. Photo-cells must be supplied with power.

Refer to the safety instructions in the front of this manual for

more information.

Controls must be installed a minimum of 10-feet from the gate

or installed in such a way that the person using the control
cannot come in contact with the gate or gate operator.

All inputs to the 4502 circuit board are Normally Open (N.O.).

SW 1

SW 2

SW 1, switch 3
must be ON.

1

ON

2

3

4

5

6

7

8

SW 1

15

20