7 loop detector wiring, Reverse rev erse shadow automat ic exit – DoorKing 6100 User Manual

Page 22

Advertising
background image

6050-065-L-11-08

20

Reverse loop lead in
wires are twisted
approx. 6 twists per
foot and are wired in
series.

Shadow loop lead
in wires are twisted
approx. 6 twists
per foot.

Automatic exit loop
lead in wires are
twisted approx. 6
twists per foot.

Reverse

Rev

erse

Shadow

Automat

ic Exit

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

NC

NO

POWER

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8

2.7 Loop Detector Wiring

If other detectors are used, use a separate power

supply to power these detectors.

Loop layout shown is for a typical swing gate

application with two-way traffic, or one-way exit
only

traffic.

Refer to the Loop Information Manual (available

from

www.dkaccess.com

) for more information

on loops and loop detectors.

Loops and loop detectors MUST be installed with this gate operator
to help prevent the gate from accidentally closing on vehicular traffic.

Loop detector wiring is shown for DoorKing plug-in loop

detectors only. If other loop detectors are used,
refer to the installation instructions supplied with
those detectors for wiring instructions.

Com

9410

9409

N.O.

Shadow Loop Output

1

ON

2

33

4

5

6

7

8

SW 2

SW 2

SW 1

SW 2, switch
1 and 2 must
be OFF.
switch 5,
must be OFF.

Relay must
be set to N.O.

NO

NC

4502

Advertising