7 loop detector wiring, Reverse rev erse shadow automat ic exit – DoorKing 6100 User Manual
Page 22

6050-065-L-11-08
20
Reverse loop lead in
wires are twisted
approx. 6 twists per
foot and are wired in
series.
Shadow loop lead
in wires are twisted
approx. 6 twists
per foot.
Automatic exit loop
lead in wires are
twisted approx. 6
twists per foot.
Reverse
Rev
erse
Shadow
Automat
ic Exit
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
NC
NO
POWER
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
5
6
7
8
2.7 Loop Detector Wiring
•
If other detectors are used, use a separate power
supply to power these detectors.
•
Loop layout shown is for a typical swing gate
application with two-way traffic, or one-way exit
only
traffic.
•
Refer to the Loop Information Manual (available
from
www.dkaccess.com
) for more information
on loops and loop detectors.
Loops and loop detectors MUST be installed with this gate operator
to help prevent the gate from accidentally closing on vehicular traffic.
•
Loop detector wiring is shown for DoorKing plug-in loop
detectors only. If other loop detectors are used,
refer to the installation instructions supplied with
those detectors for wiring instructions.
Com
9410
9409
N.O.
Shadow Loop Output
1
ON
2
33
4
5
6
7
8
SW 2
SW 2
SW 1
SW 2, switch
1 and 2 must
be OFF.
switch 5,
must be OFF.
Relay must
be set to N.O.
NO
NC
4502