3.1 4502 Circuit Board Adjustments

SECTION 3 - ADJUSTMENTS

The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect.

Power LED indicates that low voltage power is applied to the circuit board. Input LEDs should be OFF and will only illuminate
when an input is activated. Pulse 1 and 2 LEDs will blink as the operator(s) are running. They can be either ON or OFF when the
operator(s) are stopped. One pulse LED for each operator used (Primary/Secondary). Tracker LEDs will flash as operator data is
sent to the access
controller (DoorKing
models 1833, 1835,
1837 or 1838 only).

Auto-close timer (when
turned on) SW 1, switch 4.

Adjust from 1 second
(full counter clockwise) to
approximately 23 seconds
(full clockwise).

Dry relay contacts (terminals
16-17) can be set for
Normally Open (NO) or
Normally Closed (NC)
operation by placing the relay
shorting bar on the N.O. or
N.C. pins respectively.

11

ON

2

3

4

5

6

7

8

SW 1

Loop Detector

Loop Detector

1

23

9410

EXIT

SHADOW

SHADOW OUTPUT

REVERSE

9409

Auto-Close Timer

Dry Relay

Contact

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

NC

NO

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8

NC

NO

Set the DIP-switches
on the circuit board to
the desired setting.
See switch-setting
charts on next 2 pages.

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8

SW 1

SW 1

SW 2

SW 2

DIP-Switches

Tracker

LEDs

Power

LED

Input LEDs

Pulse 1 LED Primary Operator

Pulse 2 LED Secondary Operator

Loop

LED

Board
Ground

Board
Power

Loop

LED

4502

Advertising
This manual is related to the following products: