Digi RCM4000 User Manual

Page 104

Advertising
background image

98

RabbitCore RCM4000

Selected signals from the Rabbit 4000 microprocessor are available on header J2 of the
Prototyping Board. The remaining ports on the Rabbit 4000 microprocessor are used for
RS-232 serial communication. Table B-2 lists the signals on header J2 and explains how
they are used on the Prototyping Board.

There is a 1.3" × 2" through-hole prototyping space available on the Prototyping Board.
The holes in the prototyping area are spaced at 0.1" (2.5 mm). +3.3 V, +5 V, and GND traces
run along the top edge of the prototyping area for easy access. Small to medium circuits
can be prototyped using point-to-point wiring with 20 to 30 AWG wire between the proto-
typing area, the +3.3 V, +5 V, and GND traces, and the surrounding area where surface-
mount components may be installed. Small holes are provided around the surface-mounted
components that may be installed around the prototyping area.

Table B-2. Use of Rabbit 4000 Signals on the Prototyping Board

Pin

Pin Name

Prototyping Board Use

1

+3.3 V

+3.3 V power supply

2

GND

3

/RST_OUT Reset output from reset generator

4

/IORD

External read strobe

5

/IOWR

External write strobe

6

/RESET_IN Input to reset generator

8–15

PA0–PA7

Output, pulled high

16

PB0

CLKB (used by A/D converter RCM4000 only)

17

PB1

Programming port CLKA

18

PB2

LED DS2 (normally high/off)

19

PB3

LED DS3 (normally high/off)

20

PB4

Switch S2 (normally open/pulled up)

21

PB5

Switch S3 (normally open/pulled up)

22–23

PB6–PB7

Output, pulled high

24–25

PC0–PC1

Serial Port D (RS-232, header J4) (high)

26–27

PC2–PC3

Serial Port C (RS-232, header J4) (high)

28–29

PC4–PC5

Serial Port B (used by A/D converter RCM4000 only)

30–31

PC6–PC7

Serial Port A (programming port) (high)

32–39

PE0–PE7

Parallel I/O, Output, I0–I7

40–47

LN0–LN7

A/D converter inputs (RCM4000 only)

PD0–PD7

Output, pulled high

48

CONVERT A/D converter CONVERT input (RCM4000 only)

49

VREF

A/D converter reference voltage (RCM4000 only)

50

AGND

A/D converter ground (RCM4000 only)

Advertising