5.2.5 Analog Inputs (RCM4000 only)

Use this function to configure the A/D converter. This function will address the A/D converter in

Register Mode only, and will return an error if you try the Direct Mode. Appendix B.4.3 provides
additional addressing and command information.

unsigned int anaInConfig(unsigned int

instructionbyte, unsigned int cmd, long baud);

ADS7870 Signal

ADS7870 State

RCM3400 Function/State

LN0

Input

AIN0

LN1

Input

AIN1

LN2

Input

AIN2

LN3

Input

AIN3

LN4

Input

AIN4

LN5

Input

AIN5

LN6

Input

AIN6

LN7

Input

AIN7

/RESET

Input

Board reset device

RISE/FALL

Input

Pulled up for SCLK active on rising edge

PIO0

Input

Pulled down

PIO1

Input

Pulled down

PIO2

Input

Pulled down

PIO3

Input

Pulled down

CONVERT

Input

Pulled down when not driven

BUSY

Output

PE0 pulled down; logic high state converter is busy

CCLKCNTRL

Input

Pulled down; 0 state sets CCLK as input

CCLK

Input

Pulled down; external conversion clock

SCLK

Input

PB0; serial data transfer clock

SDI

Input

PC4; 3-wire mode for serial data input

SDO

Output

PC5; serial data output /CS driven

/CS

Input

BUFEN pulled up; active-low enables serial interface

BUFIN

Input

Driven by VREF

VREF

Output

Connected to BUFIN and BUFOUT

BUFOUT

Output

Driven by VREF