Digi RCM4000 User Manual

Page 59

Advertising
background image

User’s Manual

53

value1

is the first A/D converter channel raw count value

volts1

is the voltage or current corresponding to the first A/D converter channel value (0 to +20 V or

4 to 20 mA)

value2

is the second A/D converter channel raw count value

volts2

is the voltage or current corresponding to the first A/D converter channel value (0 to +20 V or

4 to 20 mA)

RETURN VALUE

0 if successful.
-1 if not able to make calibration constants.

SEE ALSO

anaIn, anaInVolts, anaInmAmps, anaInDiff, anaInCalib, brdInit