Rfc 2544 test parameters setup, Throughput test settings – EXFO ETS-1000 User Manual
Page 58

Configuring and Starting a Test
50
ETS-1000
RFC 2544 Test Parameters Setup
RFC 2544 Test Parameters Setup
Configure the test parameters for the Throughput, Latency, Frame loss and
Back-to-back tests.
Throughput Test Settings
The objective of this test is to find the throughput of the unit under test for
which there is no frame loss. Starting at the specified maximum rate
(Maximum Rate), the rate converges towards the highest throughput
without frame loss with the test having a predefined duration (Test Time).
The throughput measurement is performed for each defined frame size.
Enabled: Enable (Yes) or Disable (No) the throughput analysis.
Rate,%: indicates the load value, specified in the percentage of the test
flow rate. The accepted range is 1 to 100 %.
Trial, s: indicates the period of time during which the test is performed
for each of the specified frame sizes. The accepted range is 1 to
2886 seconds.