EXFO ETS-1000G User Manual
Page 88

BERT
78
ETS-1000G
ET
The time that has elapsed since the beginning of the test.
RT
The time that is left until the end of the test.
BITs
The number of received bits.
EBITs
The number of bit errors.
BER
The number of bit errors divided by the total number of
received bits.
TX Err
Number of manually injected errors.
LSS
The time during which the loss of test sequence synchroni-
zation was observed.
%LSS
The ratio of the time during which there was the loss of test
sequence synchronization to the time that has elapsed since
the beginning of the test (in percentage terms).
LOS
The time during which there was no signal.
%LOS
The ratio of the time during which there was no signal to
the time that has elapsed since the beginning of the test (in
percentage terms).
Setup
Open the BERT Setup menu.