16 impulse tests, Impulse main page – EXFO FTB-635 Wideband Copper and DSL Test Module User Manual
Page 271

Copper and xDSL Tests
263
16 Impulse Tests
The purpose of the impulse tests is to count, view, capture, and analyze VF
and Wideband impulse noise events on the line under test. Use the VF
Impulse Noise and WB Impulse Noise tests to count impulse events over
time that exceed the configured noise level threshold.
The Impulse Scope displays and captures impulse noises in the time
domain so you can analyze impulse duration and frequency. Both
continuous and capture/trigger modes are provided.
The Impulse Duration and Disruption (IDD) tests capture and show the
distribution and accumulation of impulse noise durations over time in a
histogram.
To access Impulse tests:
From the Copper main menu Test Groups, select Impulse test.
Impulse Main Page
The Impulse menu allows you to select and run the displayed tests:
VF Impulse Noise
WB Impulse Noise
Impulse Scope
Impulse Duration