Impulse Duration
Impulse Separation Time defines the shortest time between
consecutive discrete impulses, and is used for centering the impulse
on the graph. This separation time also defines the largest allowable
gap between threshold events within a single impulse.
Import from Impulse Scope button allows you to import the Impulse
Separation Time value from Impulse Scope.
Plot Interval is only enabled in the Disruption tab and allows you to
define the time period to display the impulse noise bars on the graph.
The Disruption histogram shows the sum of impulse durations that
are collected during each plot interval (bar).