4 heating system, 5 domestic hot water system – Glow-worm Compact 100E User Manual

Page 12

Advertising
background image

12

221894A

BOILER

DOMESTIC

WATER

HOT

COLD SUPPLY

FILLING
POINT

OPTIONAL FILLING
KIT AVAILABLE
No. 457120

DRAIN
POINT

’A’

FLOW
CONTROL
VALVE

HEATING
CIRCUIT

RETURN

ADDITIONAL
EXPANSION
VESSEL
(if required)

Diagram 4.3

METHOD 1

METHOD 2

METHOD 3

SUPPLY STOP
VALVE

SUPPLY
PIPE

HOSE
UNIONS

SERVICING
VALVE

TEMPORARY
HOSE

HEATING
SYSTEM

HEATING
SYSTEM

TEMPORARY
HOSE

HOSE
UNIONS

SERVICING
VALVE

SUPPLY
PIPE

SUPPLY STOP
VALVE

DOUBLE CHECK
VALVE ASSEMBLY

HEATING
SYSTEM

SERVICING
VALVE

SUPPLY
STOP VALVE

SUPPLY
PIPE

HOSE
UNIONS

DOUBLE CHECK
VALVE ASSEMBLY

OVERFLOW

CISTERN

COMBINED
CHECK VALVE
AND VACUUM
BREAKER

PRESSURE
REDUCING
VALVE

3132

6951

Diagram 4.2

4 Heating System

5.1 General

The domestic hot water service must be in accordance with the
rules in force in the countries of destination.

5.2 Water Pressure

For the minimum and maximum working pressures of the
domestic hot water circuit of the boiler refer to diagram 1.2.

If the cold water supply pressure exceeds the maximum, a
governor must be fitted in the supply to the boiler to reduce the
pressure to within the limits given.

ALTERNATIVE METHODS OF FILLING

5.3 “Hard” Water Areas

In areas where the water is “hard”, more than 200mg/litre, it is
recommended that a proprietary scale reducer is fitted in the
cold water supply to the boiler. Consult the local water company
for additional advice.

A double check valve assembly must be fitted upstream of the
scale reducer. For the relative position of the scale reducer and
pressure reducing valve, if required, refer to the manufacturer’s
instructions.

5 Domestic Hot Water System