8 mounting the boiler – Glow-worm Compact 100E User Manual
Page 19

19
221894A
7308
Diagram 8.11
FAN
FLUE
DUCTING
FLUE
CONNECTING
SLEEVE
8 Mounting the boiler
7307
Diagram 8.13
7306
Diagram 8.14
FAN
FLUE
DUCTING
FLUE
CONNECTING
SLEEVE
SECURING
SCREW
RETAINING
LIP
FLUE
DUCTING
FLUE
CONNECTING
SLEEVE
FLUE
COLLECTOR
RETAINING
LIP
FAN
(Push up
to fit)
AIR
PRESSURE
TUBE (2)
ELECTRICAL
CONNECTIONS
CLEAR
RED
FLUE OUTLET
RESTRICTOR TABLE
Fit the flue connecting sleeve on to the fan, see diagram 8.12.
Fit the fan to the flue ducting, Holding it up in position fit the flue
collector, see diagram 8.13.
Secure the fan to the flue collector with the securing screw and
retaining lip, see diagram 8.14.
Fit the electrical connections and air pressure tubes to the fan.
Refit the combustion chamber panel.
Make the outer wall weatherproof. A Flue Collar Kit Part No.
443286 is available.
Up to 2.5M
Up to 2.5M
Up to 2.5M
Up to 2.5M
Case Rear
Top LHS
Top RHS
Top Rear
Max. flue length
Restrictor Plate Max. flue length
Restrictor Plate
G
C
C
C
N/A
2.5 to 3.5M
2.5 to 3.5M
2.5 to 3.5M
N/A
Non
D
D
7404
Diagram 8.12
Push
to fit
FAN
FLUE
CONNECTING
SLEEVE