8 mounting the boiler – Glow-worm Compact 100E User Manual

Page 19

Advertising
background image

19

221894A

7308

Diagram 8.11

FAN

FLUE
DUCTING

FLUE
CONNECTING
SLEEVE

8 Mounting the boiler

7307

Diagram 8.13

7306

Diagram 8.14

FAN

FLUE
DUCTING

FLUE
CONNECTING
SLEEVE

SECURING
SCREW

RETAINING
LIP

FLUE
DUCTING

FLUE
CONNECTING
SLEEVE

FLUE
COLLECTOR

RETAINING
LIP

FAN
(Push up
to fit)

AIR
PRESSURE
TUBE (2)

ELECTRICAL
CONNECTIONS

CLEAR

RED

FLUE OUTLET

RESTRICTOR TABLE

Fit the flue connecting sleeve on to the fan, see diagram 8.12.

Fit the fan to the flue ducting, Holding it up in position fit the flue
collector, see diagram 8.13.

Secure the fan to the flue collector with the securing screw and
retaining lip, see diagram 8.14.

Fit the electrical connections and air pressure tubes to the fan.

Refit the combustion chamber panel.

Make the outer wall weatherproof. A Flue Collar Kit Part No.
443286 is available.

Up to 2.5M

Up to 2.5M

Up to 2.5M

Up to 2.5M

Case Rear

Top LHS

Top RHS

Top Rear

Max. flue length

Restrictor Plate Max. flue length

Restrictor Plate

G

C

C

C

N/A

2.5 to 3.5M

2.5 to 3.5M

2.5 to 3.5M

N/A

Non

D

D

7404

Diagram 8.12

Push
to fit

FAN

FLUE
CONNECTING
SLEEVE

Advertising