13 fault finding, 2 clock/timer – Glow-worm Compact 100E User Manual

Page 28

Advertising
background image

28

221894A

13.2 Clock/Timer

If the clock has failed it can be bypassed by disconnecting the
plug and reconnecting the link, see diagram 13.1.

Gain access by removing the two screws securing the controls
facia, see diagram 9.1.

Hinge the control facia forward.

Remove the clock timer cover, see diagram 10.2.

Disconnect the clock wiring harness plug and connect the link.

This is a temporary measure and the clock should be repaired
or replaced as soon as possible.

13 Fault Finding

Diagram 13.1

7025

CLOCK/TIMER
PLUG

LINK

CLOCK/TIMER

7467

Diagram 13.2

MAINS FUNCTIONAL FLOW

7670

LOW VOLTAGE
FUNCTIONAL FLOW

F1 T2A

yellow

black

brown

blue

red

brown

brown

brown

black

N

OVERHEAT

CUTOFF

PRESSURE

DIFFERENTIAL

CONTROL BOARD

GAS

VALVE

CLOCK

TIMER PLUG

WATER

DIVERTER

VALVE

ON/OFF

SWITCH

TERMINAL

BLOCK

SPARK

ELECTRODES

PERMANENT
MAINS 230V-50HZ

FAN

PUMP

X3

X3

X3

X3

X2

white

X2

brown

X11

black

X11

blue

X11

X1

X1

X1

X1

X2

X2

X2

X2

L

grey

grey

AIR

PRESSURE

SWITCH

red

black

blue

blue

X3

X3

yellow

yellow

white

grey

orange

PCB

purple

white

black

X5

X5

X4

X4

X4

X4

X4

X3

X3

X5

DHW

FLOW

SWITCH

purple

purple

orange

orange

X5

CH THERMISTOR

DHW THERMISTOR

CONTROL BOARD

N/C

N/O

C

grey

black

white

WATER

PRESSURE

SWITCH

1

2

CLOCK

TIMER PLUG

EXTERNAL

CONTROLS

Advertising