1 General Data

6942

1.1 Installation

Materials and equipment should be fit for their purpose and of
suitable quality and workmanship.

1.2 Important Notice

This boiler is for use only on natural gas, G20.

1.3 Sheet Metal Parts

WARNING. When installing or servicing this boiler care should
be taken when handling the edges of sheet metal parts to avoid
any possibility of personal injury.

1.4 Requirements

The installation of this boiler must be carried out by a competent
person in accordance with the current rules in force in the
countries of destination at the time of installation.

Manufacturer’s instructions, supplied.

Manufacturer’s instructions must not be taken as overriding
statutory requirements.

1.5 Data Label

The data label is on the inner case front, see diagram 1.2.

1.6 Data

See table 1 and diagrams 1.1, 1.2 & 1.3.

The Seasonal Efficiency Domestic Boilers UK (SEDBUK) is
78.3%.

The value is used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data
from which it has been calculated have been certified by B.S.I.

Diagram 1.1

Optional flue kits are available
Horizontal top outlet and Vertical.

Lift Weight

31.7kg (69.89b)

Total Weight

41.1kg (90.61lb)

Gas connection

Ø 15mm compression

Heating and return

Ø 22mm compression

Domestic hot water

Ø 15mm compression

Safety valve

Preset 3bar (43.5lbf/in

2

)

Safety valve discharge

Ø 15mm copper

Water content

1.42 litres (0.31 gallon)

Expansion vessel capacity 6 litres (1.32 gallons)

Heating cold fill

0.7bar

pressure minimum

(10.1lbf/in

2

)

D.H.W

0.8 to 10bar

working pressure

Maximum Heating

60 litres

system water

(13.2 gallons)

content using

with a cold

fitted expansion

fill pressure

vessel.

of 0.7bar

Electrical supply

230V~50Hz

Electrical rating

150W fused 3A

Internal Fuse rating

1) Type T2A

■ For larger systems use an additional expansion

vessel, see Section 4.

❋ Boiler starts at an inlet pressure of 0.5bar but

requires 0.8bar for maximum output.

TABLE 1

C

M

N

P

A

D

E

B

G

CL

CL

H

9mm

J

L

K

K

F

D

E

Approximate gas

3.03m

3

/h

rate at max input

(107ft

3

/h)

EXTD. EASYFIT

A

B

C

D

E

F

G

H J K L M N

P

450

700

300

100

75

138

142

18

135 65 110 138 85 115 103