14 replacement of parts – Glow-worm Compact 100E User Manual

Page 34

Advertising
background image

34

221894A

14 Replacement of Parts

Diagram 14.8

6982

CONTROL
BOARD

IGNITION LEADS

SUPPORT
POSTS (4)

Diagram 14.9

SOCKET
HEAD
CAPSCREW
(8)

GAS SUPPLY
PIPE)

GAS
CONTROL
VALVE

6986

MANIFOLD

MULTI PIN
CONNECTOR

14.10 Pump

Before starting refer to Section 11.

Remove the two screws securing the controls facia, see diagram
9.1.

Hinge the assembly open.

Release the water pressure and drain the central heating circuit
of the boiler, refer to Section 11.3 and 11.6.

Remove the electrical plug at the pump, see diagram 14.10.

Remove the four cap head screws, see diagram 14.10.

Make sure that the pump is fitted in the correct orientation.

The pump adjuster on the new pump should be set to that of the
original, refer also to Section 4.4.

The flow rate should be controlled by means of a valve in the
heating flow, refer to Section 4.6.

14.11 Low Water Pressure Switch

Before starting refer to Section 11.

Remove the two screws securing the controls cover door and
controls fascia, see diagram 9.1.

Hinge the assembly open.

Release the water pressure and drain the central heating circuit
of the boiler, refer to Section 11.3 and 11.6.

Diagram 14.10

ELECTRICAL
SUPPLY
LEADS

SPINDLE

6988

PUMP

PLUG

END
SCREW

TERMINAL
COVER SCREW

PUMP
ADJUSTER

SECURING
SCREW 4)

7244

Diagram 14.7

SECURING SCREW

CAREFULLY BEND THE
RETAINING CLIPS FORWARD
TO RELEASE MULTI PIN
CONNECTORS

MULTI PIN
CONNECTORS

SENSING LEAD

Advertising