14 replacement of parts – Glow-worm EnergySaver 80 User Manual

Page 34

Advertising
background image

34

221837B

Diagram 14.3

14 Replacement of Parts

4065 S

ELECTRICAL
PLUG

SUPPORT
POST (2)

CONTROL
P.C.B.

IGNITION
LEAD

SUPPORT POST (4)

TERMINAL
STRIP

I.C.B

ELECTRICAL
PLUG (5)

Control PCB: diagram 14.3 (top)

Disconnect the electrical plug on the board.

Release from its two support posts and carefully pull the board
away noting that the ignition lead is still connected.

It may be necessary to hold some of the wires above the PCB
clear with an electrical screwdriver on removal or refitting.

Release and carefully pull the board away from its supports,
noting that the ignition lead is still connected.

Disconnect the ignition lead.

Interconnecting PCB: (ICB) diagram 14.3
(bottom)

Disconnect the electrical plugs and cables from the terminal
strip.

Release and carefully pull the board away from its supports.

When refitting refer to wiring diagram 13.2.

14.4 Control Thermostat and Overheat Cutoff

Release the control box, see Section 9.

Control Thermostat: diagram 14.4A and 14.4

Pull off the control thermostat and High/Low knobs.

Remove the three fascia securing screws and fascia.

Remove the electrical connections from the control thermostat
body.

Remove the two control thermostat securing screws.

Release and remove the control thermostat phial from the
pocket.

Withdraw the capillary through the controls box grommet.

Slide control thermostat body away from control box.

On replacement smear the phials with the heat sink compound
supplied before replacing in the phial pocket.

When refitting refer to wiring diagram 13.2.

Overheat Cutoff: diagram 14.4A and 14.4

Remove the electrical connections.

Remove the locking nut.

Release and remove the overheat cutoff phial from the pocket.

Withdraw the capillary through the controls box grommet.

On replacement smear the phials with the heat sink compound
supplied before replacing in the phial pocket.

When refitting refer to wiring diagram 13.2.

Neatly secure any surplus capillary.

Flue Hood Overheat Cutoff: diagram 14.5

Remove electrical connections and unfasten the screws to
release.

Note: the polarity of the connections is not important.

Advertising