14 replacement of parts – Glow-worm EnergySaver 80 User Manual
Page 35
35
221837B
Diagram 14.4
Diagram 14.4A
14 Replacement of Parts
Diagram 14.5
4067 S
4078 S
4377 S
4066 S
CONTROL THERMOSTAT
SECURING SCREW (2)
OVERHEAT
CUT OFF
LOCKNUT
ELECTRICAL
CONNECTION (5)
RETAINING
PIN
OVERHEAT CUT
OFF PHIAL
CONTROL
THERMOSTAT
PHIAL
RESET
BUTTON
PLASTIC
OVERHEAT
THERMOSTAT
CONTROLS
FASCIA
SECURING
SCREW (3)
CONTROL
THERMOSTAT
KNOB
HIGH/LOW
CONTROL
KNOB
CONTROLS
FASCIA
14.5 “High/Low” Control: diagram 14.4 and
14.6
Remove the fascia as described in Section 14.4.
Remove the four screws securing the lights bracket.
Remove the locknut to release the “High/Low” control.
Disconnect the three in-line electrical connectors.
When refitting refer to wiring diagram 13.2.
14.6 Air Pressure Switch: diagram 14.7.
Remove the air pressure tubes and electrical connections.
Remove the two securing screws to release the air pressure
switch.
When fitting the replacement make sure that all the air pressure
tubes and electrical connections are made as shown.