Installation, Continued, Built-in fireplace installation – Desa EFS33NRB User Manual

Page 11

Advertising
background image

www.desatech.com

113132-01A

11

11. Carefully insert fireplace into cabinet mantel.

Be careful not to scratch or damage hearth base,
cabinet mantel, or any laminate trim on hearth
base. Remove protective material from top of
hearth base and from front of fireplace (if any).

Note:

You can secure fireplace to hearth or

floor. Open lower louver. Locate screw holes
in bottom of base. Tighten wood screws through
these holes and into hearth or floor.

12. Check all gas connections for leaks. See

Checking Gas Connections, pages 15 and 16.

INSTALLATION

Continued

Figure 12 - Inserting Fireplace Into

Cabinet Mantel

;;;;;

;;;;;

QQQQQ

QQQQQ

;;;

;;;

;;;

;;;

;;;

QQQ

QQQ

QQQ

QQQ

QQQ

Actual

Framing

Height

32

3

/

8

"

33"

Front Width

34

5

/

16

"

35

1

/

2

"

Depth

16

11

/

16

"

17

3

/

4

"

BUILT-IN FIREPLACE
INSTALLATION

Built-in installation of this fireplace involves in-
stalling fireplace into a framed-in enclosure. This
makes the front of fireplace flush with wall. If in-
stalling a mantel above the fireplace, you must fol-
low the clearances shown in Figure 16, page 12.
Follow the instructions below to install the fire-
place in this manner.

1.

Frame in rough opening. Use dimensions shown
in Figure 13 for the rough opening. If installing
in a corner, use dimensions shown in Figure 14
for the rough opening. The height is 33" which
is the same as the wall opening above.

2.

If using blower, install and properly ground
GA3555, three-prong 120 volt electrical outlet,
in fireplace. Follow instructions included in kit.

3.

Install gas piping into fireplace location. This
installation includes an approved flexible gas
line (if allowed by local codes) after the equip-
ment shutoff valve. The flexible gas line must
be the last item installed on the gas piping.
See Installing Gas Piping to Fireplace Loca-
tion,
pages 12 and 13.

4.

Carefully set fireplace in front of rough open-
ing with back of fireplace inside wall opening.

5.

Carefully insert fireplace into rough opening.

6.

Attach flexible gas line to gas supply. See
Connecting Fireplace to Gas Supply, page 14.

7.

Attach fireplace to wall studs using nails or
wood screws through holes in nailing flange
(see Figure 15).

8.

Check all gas connections for leaks. See
Checking Gas Connections, pages 15 and 16.

9.

Plug electrical cord into electrical outlet in-
stalled in step 2.

10. Install trim after final finishing and/or paint-

ing of wall (see Figure 7, page 9).

Figure 13 - Rough Opening for Installing

in Wall

Figure 14 - Rough Opening for Installing

in Corner

Figure 15 - Attaching Fireplace to Wall

Studs

35

1

/

2

"

17

3

/

4

"

33"

39

3

/

8

"

27

7

/

8

"

55

5

/

8

"

35

1

/

2

"

Nailing
Flanges

Nails or Wood
Screws