Cleaning and maintenance, Wiring diagram, Specifications – Desa EFS33NRB User Manual

Page 22: Continued

Advertising
background image

www.desatech.com

113132-01A

22

6.

In case any large clumps of dust have now been
pushed into the burner repeat steps 3 and 4,
page 21.

Clean the pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about
two inches from where the pilot flame comes out
of the pilot assembly (see Figure 39). With the
unit off, lightly blow air through the air inlet hole.
You may blow through a drinking straw if com-
pressed air is not available.

LOGS

• If you remove logs for cleaning, refer to In-

stalling Logs, page 16, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized

or larger).

Figure 39 - Pilot Inlet Air Hole

Burner
Tube

Pilot
Assembly

Pilot Air
Inlet Hole

Ports/
Slots

CLEANING AND

MAINTENANCE

Continued

AUT

O

OFF

ON

Thermopile

WIRING DIAGRAM

Note:

For proper operation of optional accesso-

ries, the wires from the switch to the control must
be connected exactly as shown.

SPECIFICATIONS

MODELS EFS33NRB and VSGF33NRB

Btu (Variable)

20,000/33,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

Minimum*

5"

Shipping Weight

122 lbs.

* For input adjustment

MODELS EFS33PRB and VSGF33PRB

Btu (Variable)

20,000/33,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

7.9" W.C.

Inlet Gas Pressure (in. of water)

Maximum

13"

Minimum*

11"

Shipping Weight

122 lbs.

* For input adjustment

Advertising