INSTALLATION

Continued

Figure 6 - Assembling Perimeter Trim

ASSEMBLING AND ATTACHING
OPTIONAL PERIMETER TRIM
(Included with Mantel Accessory)

IMPORTANT:

If you are recessing the firebox in

a wall, do not attach trim at this time. See Built-In
Fireplace Installation
, pages 11 and 12.

Note:

The instructions below show assembling and

attaching trim to fireplace.

1.

Remove packaging from three pieces of trim.

2.

Locate four screws, two adjusting plates
with set screws, and two shims in the hard-
ware packet.

3.

Align shim under adjusting plate as shown in
Figure 6.

4.

Slide one end of adjusting plate/shim in slot
on mitered edge of top trim (see Figure 6).

5.

Slide other end of adjusting plate/shim in slot
on mitered edge of side trim (see Figure 6).

6.

While firmly holding edges of trim together,
tighten both set screws on the adjusting plate
with slotted screwdriver.

7.

Repeat steps 1 through 6 for other side.

8.

Tighten trim hanging screws (#10 x 6.25
shoulder) into holes in cabinets. Place the as-
sembled trim onto fireplace cabinet. Align
hanging notches on trim with hanging screws
on side of fireplace (see Figure 7). Push trim
firmly into place, sliding hanging notches over
hanging screws.

Side Trim

Slot

Mitered Edge

Slot

Shim

Set Screws

Adjusting
Plate

Assembled
Trim

Top
Trim

Figure 7 - Attaching Perimeter Trim to

Fireplace (VSGF33NRB Shown)

Trim
Hanging
Screws

Hanging
Notches
on Trim

INSTALLATION CLEARANCES

WARNING: Maintain the

minimum clearances. If you can,
provide greater clearances from
floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will
ensure safe installation.

Minimum Clearances For Side Combustible
Material, Side Wall, and Ceiling

A. Clearances from the side of the fireplace cabi-

net to any combustible material and wall
should follow diagram in Figure 8.

Example:

The face of a mantel, bookshelf,

etc. is made of combustible material and pro-
trudes 3

1

/2" from the wall. This combustible

material must be 4" from the side of the fire-
place opening (see Figure 8).

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 42 inches.

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Bottom

Right Sides

and Rear

0"

16"

0"

*

*Minimum 16 inches from Side Wall

Example

Figure 8 - Minimum Clearance for

Combustible to Wall