6. WIRING THE A.C. INPUT

A. The

ILB-3020 and A.C. driver must be on the same branch circuit.

B. The

ILB-3020 requires an unswitched A.C. power source of either 120 or 277 volts. Select the proper voltage

lead and cap the unused lead.

C. When the

ILB-3020 is used with a switched fixture, the A.C. input to the ILB-3020 must be connected ahead of

the fixture switch. Refer to Illustration 3 for switched and unswitched fixture wiring diagrams.

BLACK

A.C. BALLAST

HOT A.C. LINE

WHITE

(120V) BLK

(277V) ORG

TEST SWITCH

COMMON

WHITE

BLACK

A.C. BALLAST

HOT A.C. LINE

WHITE

(120V) BLK

(277V) ORG

TEST SWITCH

COMMON

Select proper voltage lead. Cap unused lead.

WALL SWITCH

WHITE

BLK/ORG

BLK/ORG lead for Cold-Weather Unit only.
For non-Cold Weather Units, cap BLK/ORG lead.
For Cold-Weather Unit 120V installation, connect BLK/ORG to BLK.
For Cold-Weather Unit 277V installation, cap BLK/ORG and BLK separately.

BLK/ORG

Select proper voltage lead. Cap unused lead.

BLK/ORG lead for Cold-Weather Unit only.
For non-Cold Weather Units, cap BLK/ORG lead.
For Cold-Weather Unit 120V installation, connect BLK/ORG to BLK.
For Cold-Weather Unit 277V installation, cap BLK/ORG and BLK separately.

Illustration 3

Switched Fixture

Unswitched Fixture

ILB-

3020

ILB-

3020

LED

DRIVER

LED

DRIVER

7. LABELS

Attach the appropriate labels adjacent to the

Test Switch and Charge Indicator. Annotate Re-lamping label for

lamp type and wattage. The Caution and the Re-lamping labels must be on the fixture in a readily visible location
to anyone attempting to service the fixture.

8. COMPLETING INSTALLATION

When the installation is complete, switch the A.C. power on and join the

ILB-3020 unit connector.

OPERATION

Normal Mode – A.C. power is present. The A.C. driver operates the LED light bar(s) as intended. The ILB-3020 is in the
standby charging mode. The

Charge Indicator will be lit providing a visual indication that the battery is being charged.

Emergency Mode – The A.C. power fails. The ILB-3020 senses the A.C. power failure and automatically switches

to the Emergency Mode. One or multiple LED light bars are illuminated, for a minimum of 90 minutes. When the A.C.

power is restored, the

ILB-3020 switches the system back to the Normal Mode and resumes battery charging. See

page 1 of the Instruction Manual.

TESTING & MAINTENANCE

Pressing the

Test Switch turns off the light on the Charge Indicator and forces the unit into emergency mode, inter-

rupting power to the designated A.C. driver. The light bar is now being lit by the

ILB-3020 unit. After releasing the Test

Switch, the fixture returns to normal operation after a momentary delay. To simulate a “BLACK OUT” use the circuit
breaker to turn off A.C. power.
Initial Testing – Allow the unit to charge approximately 1 hour, then conduct a short discharge test. Allow a 24 hour
charge before conducting a 90 minute test.
The

ILB-3020 is a maintenance free unit, however, periodic inspection and testing is required. NFPA 101, Life Safety

Code, outlines the following schedule:
Monthly – Insure that the Charge Indicator light is illuminated. Conduct a 30 second discharge test by depressing the
Test Switch. At least one light bar should operate at reduced output.
Annually – Insure that the Charge Indicator is illuminated. Conduct a full 90 minute discharge test. The unit should
operate as intended for the duration of the test.

“Written records of testing shall be kept by the owner for inspection by the authority having jurisdiction.”

SERVICING SHOULD BE PERFORMED BY QUALIFIED PERSONNEL.