Laerdal Nursing Anne (SimPad Capable) User Manual

Page 7

Advertising
background image

Nursing Anne

5

Laerdal

Figure 8

Colon Reservoir –

Colon reservoir inserts into pelvic

cavity with narrow end downward

and connector pointing outward .

This connector attaches reservoir

to anal valve on genitalia .

(Photo 8)

Reservoir should be removed from

manikin, inverted, drained and

completely air-dried before storing .

Urinary Catheterization and Enema Simulation –

Catheters should be well lubricated with manikin lubricant or full

strength liquid soap prior to using .

After several uses, catheter may “hang” when water has washed away

lubricant, causing friction and binding . If this occurs, generously

lubricate a catheter and insert into urethra several times .

If catheter hangs during removal, work it with an “in and out” motion .

Use warm water in reservoirs when possible to keep soap from clogging

the catheters . Make sure reservoirs are well drained of all water before

disconnecting valves .

Check List for Valves That May Leak:

a. Do valve connections have an O-ring?

b. Does the white clamp fit firmly against base of valve?

c. Are valves attached correctly?

d . If valves are attached correctly, are they properly connected to

reservoirs and to genitalia?

A size 16 French catheter is suggested for urethral catheterization .

Size 7mm catheter is suggested for enema simulation .

Troubleshooting –

What can I do if my manikin develops a pelvic spread?

Cinch pelvis with a belt and heat with a hair dryer to soften, cinching as

you heat . Insert pin, leaving belt in place until cool .

What do I do if my connectors leak?

Make sure C-clamps are squeezed tightly into place and connectors are

screwed on tightly .

What can I do if I can’t remove my catheter?

Make sure the cuff is deflated .

Attaching Nursing Anne Modules to Manikin:

Fundus Skills Module - Legs, internal components and genitalia must be

removed from pelvis .

Applying baby powder to skin and modules will assist

in attachment and removal .

To remove legs:

1 . Remove abdominal plate by pulling up on its edges .

2 . Remove genitalia and all internal attachments, reservoirs and

pelvic pin . (If using sounds abdominal plate, detach cable .)

3 . Remove thigh injection pad by squeezing skin in center of pad

while pulling .

4 . Locate wing nut on inside of pelvis .

5 . Using screwdriver to hold bolt in place,

twist and remove wing nut .

6 . Remove spring and small washer from bolt .

(Figure 8)

7 . Remove bolt from thigh and pelvis .

To attach Fundus Module:

1 . Apply baby powder to pelvis and inner fundus skin .

2 . Remove silicone straps from cut portion at back of fundus skin .

3 . Slide skin up and over pelvis, with slit and straps positioned

on posterior side of manikin .

4 . Reattach legs . (Legs must be reattached at this point, without

proceeding further with fundus upgrade assembly .) When

reattaching legs, make sure to leave space in between thigh

and skin to allow for leg articulation without rubbing against

fundus skin .

5 . Pull fundus skin partially down pelvis, exposing internal

pelvic area .

6 . Place fundus foam bottom inside pelvis .

7 . Using connectors, connect genitalia to urinary reservoir .

8 . Place genitalia/urinary reservoir inside pelvis . This must be done

from the genitalia area . Go through

the genitalia opening to

place the reservoir and

genitalia . (Photo 9)

9 . Place symphysis pubis

pelvic pin . This replaces

the pelvic pin already

located in the manikin .

(Photo 9)

10 . Pull fundus skin up and

attach three (3)

tabs at back .

11 . Insert “firm” or “boggy”

fundus ball .

Photo 8

Fundus skin

Symphysis Pubis

Genitalia

Urinary Bladder

Connector

Fundus Foam Bottom

English

8 .

9 .

Photo 9