Sounds, Eyes settings and configurations, Drugs and iv – Laerdal SimMan Essential Bleeding User Manual

Page 11: Simman essential bleeding clothing, Features, Body sounds, Vocal sounds, Eyes, Patient monitor features – drugs, User-replaceable items, spare parts

Advertising
background image

11

FEATURES

Sounds

Two types of sounds can be used in a scenario:

– Body sounds

– Vocal Sounds

The sounds can be triggered by the scenario or controlled by the
instructor.

Body Sounds

The body sounds are simulated sounds from a human body, like
heart, lungs, and bowel sounds. The sounds are integrated and
generated in the Patient Simulator and transferred through the
integrated speakers.

Vocal Sounds

The vocal sounds are sounds from the throat like coughing, moaning,
and crying as well as spoken words. The sounds are integrated in
LLEAP.

In addition, the instructor can communicate through a microphone
and the voice is then transferred to the Patient Simulator through
the VCA.

Note: A variety of settings for Sounds can be made in LLEAP. See
LLEAP Help for further information

Eyes Settings and Configurations

The calculated Glasgow Coma Scale score for the Patient Case is
displayed in LLEAP. The following sources of information helps the
learner to judge the state of disability:

Eyes

− Blinking eyelids

− Eyelids: open, closed or partially open

− Eyelids can be opened for examination by the learner

− Set of interchangeable pupils available

Note: A variety of settings for Circulation and Fluids can be made
in LLEAP. See LLEAP Help for further information.

Drugs and IV

Drugs and drug concentrations can be registered manually by the
instructor in LLEAP.

Patient Monitor Features – Drugs:

– Train-of-Four (TOF)

– in N

2

O, et N

2

O

– Anesthesia agents

– Lab reports

User-Replaceable Items, Spare Parts:

– Intra-muscular Pad

– Tibial IO Pad

Vascular Access (IV and IO) Locations

Intraosseous access with needle insertion is possible through the left
tibia. The IO pads may be punctured numerous times before being
replaced.

To replace the IO modules, see the Simulation Setup section.

Caution: Do not inject fluids into these pads unless approved IO

modules with fluid outlets are in place.

Intra-muscular (IM) Injection

Use the pad placed under the Torso Skin on the right buttock for
intramuscular injection training.

SimMan Essential Bleeding

Clothing

Included with the Patient Simulator:

− Shirt, with side zippers

− Trousers, with full-length side zippers

− Boxer shorts underwear

− Belt

Note: For washing instructions see care labels.

Simulated Removal of the Clothes

To simulate cutting with scissors: unzip the zippers placed alongside
the seams on both sides.

Cautions

and

W

arnings

Featur

es

Setup

Maintenance

Spar

e Par

ts

Tr

oubleshooting

Advertising