N-Series Isolation Poppet Valves

7.4 Replacement or Add-On Position Indicator

Solenoid test:
Insert air supply line into the straight fitting on the solenoid.
Apply 60 to 100 psi air pressure.
Valve should not open until power is applied. Verify valve opens with power is applied and closes when
power is removed.
Alternately you can actuate the solenoid valve by pressing the manual actuation button.

5

The N-Series valve position indicators are mounted on a printed circuit board which, in turn, is located in a preformed slot in the top housing of the valve. It is
held in place by the label on top of the valve. This label must be removed in order to access the position indicator circuit board. As such, the position indicator
replacement or add-on kit includes a spare label to be used, since the original adhesive likely will not be adequate to be used a second time.
The position indicator kit can be ordered under part number N-O-K.
Position indicator kit includes the circuit board, connection cable and top label.
To add or replace the N-Series position indicator, please see the following instructions :

1

Place label onto valve as shown
so the electrical connector is
accessible through the opening
in the label.
Reinstall the air fitting.

2

BLACK -Ground

GREEN - Closed

WHITE - Open

RED - +24 VDC

Connect position indicator cable
as shown.
Connect air line for normal valve
operation.

3

Input: +5 to +28 VDC

Output: NPN Standard
PNP Option available on request

Remove the air fitting if installed.
Remove the label to access the
position indicator card slot.
Replacement label is included in
the kit.
Install the sensor board with the
optics toward the stem, and the
electrical connector located at the
top of the valve facing away from
the stem.
Do Not wear latex gloves when
handling boards!!!

When the valve is in the closed
position the “0” led should illu-
minate on the valve as shown

4

When the valve is in the open
position the “I” led should illu-
minate on the valve as shown.