Nor-Cal N-Series Op Lit User Manual

Page 4

Advertising
background image

4

4

Visit our Web Site

www.n-c.com

N-Series Isolation Poppet Valves

3.0 - Specifications

The following figures and tables summarize specifications of the N-Series vacuum valve.

TABLE 3.1 ENVIRONMENTAL SPECIFICATIONS

Feature

SPeCIFICatION

Installation Orientation

Product may be installed in any orientation, with gas flow in either direction.

Ambient Operating Temperature Range

32

o

– 122

o

F (0

o

C – 50

o

C)

Allowable Ambient Humidity

0

– 95% non-condensing

Process Temperature Range

0

o

F

– 392

o

F (-18

o

C

– 200

o

C). Process temperatures above 302

o

F (150

o

C), may require use of seal materials other than

Viton®.

Heating Capabilities

Body can be heated up to 302

o

F (150

o

C) with optional heater kits.

Maximum internal Pressure

20 psi (138 kPa).

Maximum delta-P across poppet

30 psi (206 kPa) in open direction. 35 psi (241 kPa) in closing direction.

TABLE 3.2 OPERATIONAL SPECIFICATIONS

Feature

SPeCIFICatION

Open / Close speed

0.5 seconds to open, 0.7 seconds to close at 80 psig.

Pneumatic Supply

60

– 100 psig (414

– 689 kPa) CDA or N

2.

Standard connection accepts 5/32” [4MM] OD tubing.
Thread is 10-32 [M5].

Solenoid Electrical Specifications

120 VAC: 2.5 Watt (-S11 option code)
24 VDC: 1.8 Watt (-S21 option code)
240 VAC: 4.0 Watt (-S31 option code)
24 VAC: 4.0 Watt (-S41 option code)

Position Indicators

Optical: Standard NPN type (-0 option code)
Optical: Optional PNP type (-02 option code)

Reliability

3 million cycles MTBF at 90% confidence factor, clean environment

TABLE 3.3 CERTIFICATION

Feature

SPeCIFICatION

Leak Rate

1 x 10

-9

atm.scc/sec He (for valves with Viton® seals)

Advertising