Page 165: Moistener  maintenance

Advertising
background image

DM825™ and DM875™ Series Digital Mailing System Operating Guide

SV62200 Rev. C

9 - 5

2. Remove the cap from the

bottle.

3. Add enough E-Z Seal® to bring

the level up to the bottom of the
fill cap.

4. Replace and tighten the cap and replace the bottle. The nozzle should

be facing down and the flat side of the bottle facing the front of the sys-
tem.

5. Close the feed cover.

Priming the
Moistener

Prime the moistener if you intend of running mail immediately after refilling
the E-Z Seal® Sealing Solution. This ensures the moistener has enough
fluid for sealing when a mail run begins.

1. Press the Seal key.
2. Press the Prime Moistener screen key.
3. Press the left arrow key to return to the Main screen.

Moistener

Maintenance

This section describes how to clean and/or replace the part of your mailing
system that moistens the flap on the envelope. This part of the mailing sys-
tem is the moistener brush assembly and consists of the moistener brush,
moistener wick and moistener tank.

If the seal quality does not improve after cleaning, you can replace the wick
or moistener brush as needed. To order replacements, refer to Chapter 11,
Supplies and Options
in this guide. Only a Pitney Bowes representative can
install a new moistener tank.

CAUTION: Do not overfill the E-Z Seal® bottle.

CAUTION: Make sure you do not spill any solution in the
tape well. If the tape gets wet, it can warp and cause a
jam.

CAUTION: Never remove the E-Z Seal® bottle and the
moistener tank at the same time. This can result in E-Z Seal®
leaking into the mailing machine.