Codabar — continued – Datalogic Scanning MAGELLAN 1400I User Manual

Page 125

Advertising
background image

Codabar

Product Reference Guide

5-49

Codabar — continued

Codabar Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to

Appendix C, Alpha-Numeric Pad

and scan the three digits (zero padded) represent-

ing the length in decimal notation.

4. Scan the END bar code.

Quiet Zones

This feature enable/disables the requirement that quiet zones must be present for Codabar bar
codes.

NOTE

For Codabar bar codes, all start, stop, check
and data characters are included in the length
calculations.

START / END

PROGRAMMING BAR CODES

DEFAULT SETTING FOR THIS FEATURE: 003

Set Length 1

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 050

START / END

PROGRAMMING BAR CODES

Don’t require Quiet Zones

DEFAULT

Require Quiet Zones

Advertising