9 Project window
9.1.9
Electronic Gearing
External Gearing Source [
GEARMODE
]
The servo amplifier can be controlled through different interfaces and from various sources.
Ratio [
GEARO
] / [
GEARI
]
You can use the entry fields in this equation to determine the transmission ratio.
Input Filter [
GEARFILT
] – PMCtendo DD5 and PMCprotego D only
This command GEARFILT can be used to configure the filter and determine the corresponding
frequency of the electronic gearing filter.
Count Direction [
DIR
]
– PMCtendo DD5 and PMCprotego D only
The DIR variable defines the count direction for feedback information.
Lines per Revolution [
ENCIN
] – PMCtendo DD4 only
ENCIN sets the resolution (number of pulses) of the encoder input channel using a digital
encoder as feedback unit.