FORM NO. L-20250-E-0114

TROUBLESHOOTING

Housing

Piston

Bearings

Bearing

Stub Shaft

Drive Disc

O-Ring

Seal

Female Pilot

Male Pilot

O-Ring Seals

Friction Facing

Splined Disc

FIGURE 9

Bar

Key

SYMPTOM

PROBABLE CAUSE

SOLUTION

Air not getting to the FMCBE due to Control
Valve malfunction.

Check for a Control Valve malfunction or low
air pressure and replace the Control Valve if

necessary.

Defective O-ring Seals resulting in air leaks.

Replace the O-ring seals.

Failure to engage (Clutch).

Lack of lubrication on Hub Spline.

Lubricate Hub Spline.

Unexhausted air due to a Control Valve
malfunction.

Check for a Control Valve malfunction and
replace the Control Valve if necessary.

Defective O-ring Seals resulting in leaks.

Replace the O-ring seals.

Failure to engage (Brake).

Lack of lubrication on Hub Spline.

Lubricate Hub Spline.

Unexhausted air due to a Control Valve

malfunction.

Check for a Control Valve malfunction and

replace the Control Valve if necessary.

Failure to disengage (Clutch).

Lack of lubrication on Hub Spline.

Lubricate Hub Spline.

Unexhausted air due to a Control Valve

malfunction.

Check for a Control Valve malfunction and

replace the Control Valve if necessary.

Failure to disengage (Brake).

Lack of lubrication on Hub Spline.

Lubricate Hub Spline.

Defective O-ring Seals resulting in air leaks.

Replace the O-ring seals.

Contaminated Friction Facings.

Replace the Friction Facings.

Loss of torque (Clutch and
Brake).

Worn Friction Facings.

Replace the Friction Facings.