Restoring the MAX II CPLD to the Factory Settings

February 2013

Altera Corporation

Transceiver Signal Integrity Development Kit,

Stratix V GT Edition User Guide

Restoring the MAX II CPLD to the Factory Settings

This section describes how to restore the original factory contents to the MAX II CPLD
on the development board. Make sure you have the Nios II EDS installed, and
perform the following instructions:

1. Set the board switches to the factory default settings described in

“Factory Default

Switch Jumper Settings” on page 4–2

.

1

Setting the switch S7.6 (MAX BYPASS) to open (1) includes the MAX II
device in the JTAG chain. Setting the switch S7.6 (MAX BYPASS) to closed
(0) removes the Max II device from the JTAG chain.

2. Launch the Quartus II Programmer.

3. Click Auto Detect.

4. Click Add File and select

<install dir>\kits\stratixVGT_5sgtea7_si\factory_recovery\max2.pof.

5. Turn on the Program/Configure option for the added file.

6. Click Start to download the selected configuration file to the MAX II CPLD.

Configuration is complete when the progress bar reaches 100%.

f

To ensure that you have the most up-to-date factory restore files and information
about this product, refer to the

Transceiver Signal Integrity Development Kit,

Stratix V GT Edition

page of the Altera website.