3 current – Applied Motion SSM23IP-2EG User Manual

Page 9

Advertising
background image

9

Rev.A

920-0090

SSM23Q/IP Hardware Manual

2.3.3 Current

The maximum supply currents required by the SSM23Q/IP are shown in the charts below at

different power supply voltage inputs. The SSM23Q/IP power supply current is lower than the

winding currents because it uses switching amplifiers to convert a high voltage and low current

into lower voltage and higher current. The more the power supply voltage exceeds the motor

voltage, the less current will be required from the power supply.

It is important to note that the current draw is significantly different at higher speeds depending

on the torque load to the motor. Estimating how much current is necessary may require a good

analysis of the load the motor will encounter.

0

0.5

1

1.5

2

2.5

3

3.5

0

0.3

0.6

0.9

1.2

1.5

0

10

20

30

40

50

To

rq

ue

(N

.m

)

Speed(RPS)

SSM23

-2EG 24V Power

A

m

ps

Continuous

Torque

Boost

Supply Current

Full Load

No Load

0

0.5

1

1.5

2

2.5

3

3.5

0

0.3

0.6

0.9

1.2

1.5

0

10

20

30

40

50

To

rq

ue

(N

.m

)

Speed(RPS)

SSM23

-2EG 48V Power

A

m

ps

Continuous

Torque

Boost

Supply Current

Full Load

No Load

Advertising