The analog input, 21 stm17 hardware manual, Gnd ain +5v out – Applied Motion STM17C-3CE User Manual

Page 21

Advertising
background image

The Analog (AIN) Input

The STM17 drives feature an analog input. The input can accept a signal

range of 0 to 5 VDC. The drive can be configured to operate at a speed or

position that is proportional to the analog signal. Use the

ST Configurator

software to set the signal range, offset, dead-band and filter frequency. The

STM17 drives also provide a +5VDC 100ma output that can be used to

power external devices such as potentiometers. It is not the most accurate

supply for reference; for more precise readings use an external supply that can provide the desired accuracy.

Example connection diagram:

Connecting a Potentiometer to the Analog Input

inside drive

AIN

GND

Signal

Conditioning

+5V

50ma Limit

I/O

Conne

ct

or

1-10k

pot

cw

ccw

GND

AIN

+5V OUT

21

STM17 Hardware Manual

920-0034 rev A

9/30/2010