3.3.3 X3/EN and X4/AR Digital Inputs

The TSM17 drives include two single ended inputs: X3/EN and X4/AR. They can be used with

sourcing or sinking signals, 5 to 24 volts. This allows connection to PLCs, sensors, relays and

mechanical switches. Because the input circuits are isolated, they require a source of power. If

you are connecting to a PLC, you should be able to get power from the PLC power supply. If you

are using relays or mechanical switches, you will need a 5-24 V power supply.
What is COM?
“Common” is an electronics term for an electrical connection to a common voltage. Sometimes

“common” means the same thing as “ground”, but not always. In the case of the TSM17 drives, if

you are using sourcing (PNP) input signals, then you will want to connect COM to ground (power

supply -). If you are using sinking (NPN) signals, then COM must connect to power supply +.
Note: If current is flowing into or out of an input, the logic state of that input is low or closed. If no

current is flowing, or the input is not connected, the logic state is high or open.
The diagrams below show how to connect the inputs to various commonly used devices.

5 - 24

volt DC

Power

Supply

Connecting the Input to a Switch or Relay

XCOM

X3/X4

+

-

TSM17

Switch or Relay

(closed = logic low)

5 - 24

volt DC

Power

Supply

Connecting an NPN type Proximity Sensor to an Input

(when prox sensor activates, input goes low)

XCOM

X3/X4

+

-

+

NPN

Proximity

Sensor

-

output

TSM17

5 - 24

volt DC

Power

Supply

Connecting a PNP type Proximity Sensor to an Input

(when prox sensor activates, input goes low)

X3/X4

XCOM

+

-

+

PNP

Proximity

Sensor

-

output

TSM17